Application1 Deep cooling, low-temperature engineering insulation, industrial equipment, pipeline insulation, etc; Widely used in air separation equipment factories
Application2 Oxygen production air separation units, natural gas, liquid hydrogen, liquid nitrogen, liquid oxygen refrigerated transport vehicles, transport ships, etc
yukunfeng@hnxypy.com
Contact Us
DetailReview(0)

Cryogenic Perlite, also known as expanded perlite sand, for thermal insulation in low-temperature devices, is a product obtained by selecting small particles of mineral sand and heating them with natural gas as a heat source in a vertical shaft kiln. The reinforced product is sprayed with organic silicon on the surface of expanded perlite to form a hydrophobic structure. The product quality meets the requirements of European classification standards


Main Characteristics

It has characteristics such as small capacity, low thermal conductivity, good ultra-low temperature insulation performance, good chemical stability, non flammable, non-toxic, odorless, and sound absorption.


Application Area

Deep cooling, low-temperature engineering insulation, industrial equipment, pipeline insulation, etc; Widely used in air separation equipment factories, such as oxygen production air separation units, natural gas, liquid hydrogen, liquid nitrogen, liquid oxygen refrigerated transport vehicles, transport ships, etc. It has the advantages of reducing cold losses, energy and electricity consumption indicators, etc


Expanded Perlite product performance indicators:

Performance indicators of expanded perlite for low-temperature equipment


Series

Indicator Name

Unit

Performance

Type 50

Type 60

1

loose density

/m³

40~50

45~60

2

Tap density

/m³

50~60

55~70

3

Particle size (weight %

ratio)

1.0mm-0.15mm

%

≥90

≥90

0.15㎜

Throughput

%

≤8

≤8

4

Mass moisture content

(weight % ratio)

%

≤0.5

≤1

5

The angle of repose (when

stacking height is 100㎜)

ο

33~37

6

Increase in

density during filling

Manual

%

≤25

wind

blowing

%

≤35

7

The thermal conductivity is (normal pressure temperature

is 77K-310K average)

w/m.k

0.022~0.025

0.023~0.026

8

Operating temperature

-200~+800


Production can be organized according to the performance indicators required by customers. chemical compositions are below:

SiO2   75.72%~78.67%     Al2O3   12.46%~13.55%        Na2O   3.08%~3.25%